CT300 Series High Performance Close Loop Vector Inverter
Speed-adjustable ratio |
1:1000 |
Speed control accuracy |
±0.02% |
Torque control related time |
10ms |
Torque control accuracy |
5% |
Starting frequency/torque |
0Hz/200% |
Inverter type |
Power level(KW) |
Input current (A) |
Output current (A) |
Applicable motor power (KW) |
Single phase 220Vac 50/60Hz |
||||
CT300-2S-0.7-B |
0.7 |
8.2 |
4.0 |
0.75 |
CT300-2S-1.5-B |
1.5 |
14.0 |
7.0 |
1.5 |
CT300-2S-2.2-B |
2.2 |
23.0 |
9.6 |
2.2 |
Three phase 380Vac 50/60Hz |
||||
CT300-4T-0.7-B |
0.7 |
3.4 |
2.5 |
0.7 |
CT300-4T-1.5-B |
1.5 |
5.0 |
3.7 |
1.5 |
CT300-4T-2.2-B |
2.2 |
5.8 |
5.3 |
2.2 |
CT300-4T-4.0-B |
4.0 |
12.0 |
9.5 |
4.0 |
CT300-4T-5.5-B |
5.5 |
18.5 |
14 |
5.5 |
CT300-4T-7.5-B |
7.5 |
22.5 |
18.5 |
7.5 |
CT300-4T-11-B |
11 |
30.0 |
25.0 |
11 |
CT300-4T-15-B |
15 |
39.0 |
32.0 |
15 |
CT300-4T-18.5-B |
18.5 |
45.0 |
38.0 |
18.5 |
CT300-4T-22-B |
22 |
54.0 |
45.0 |
22 |
CT300-4T-30-B |
30 |
68.0 |
60.0 |
30 |
CT300-4T-37-B |
37 |
84.0 |
75.0 |
37 |
CT300-4T-45 |
45 |
98.0 |
92.0 |
45 |
CT300-4T-55 |
55 |
123.0 |
115.0 |
55 |
CT300-4T-75 |
75 |
157.0 |
150.0 |
75 |
CT300-4T-90 |
90 |
188.0 |
180.0 |
90 |
CT300-4T-110 |
110 |
221.0 |
215.0 |
110 |
CT300-4T-132 |
132 |
267.0 |
260.0 |
132 |
CT300-4T-160 |
160 |
309.0 |
305.0 |
160 |
CT300-4T-185 |
185 |
344.0 |
340.0 |
185 |
CT300-4T-200 |
200 |
384.0 |
380.0 |
200 |
CT300-4T-220 |
220 |
429.0 |
425.0 |
220 |
CT300-4T-250 |
250 |
484.0 |
480.0 |
250 |
CT300-4T-280 |
280 |
539.0 |
530.0 |
280 |
CT300-4T-315 |
315 |
612.0 |
600.0 |
315 |
CT300-4T-350 |
350 |
665.0 |
650.0 |
350 |
CT300-4T-400 |
400 |
715.0 |
720.0 |
400 |
CT300-4T-500 |
500 |
890.0 |
860.0 |
500 |
Input and output parameters |
Input voltage |
Single-phase 220VAC±15%, three-phase 380VAC±15%. |
|
Input frequency |
50~60Hz±5% |
||
Output voltage |
0~Rated input voltage |
||
Output frequency |
0~600Hz |
||
Output overload capacity |
150% of rated current: 60s, 180% of rated current: 10s, 200% of rated current: 1s |
||
Running control features |
Control mode |
V/F control, PG close loop vector control (applicable for synchronous motors and asynchronous motors) |
|
Adjustable-speed ratio |
1:1000(PG close loop vector control) |
||
Speed control accuracy |
±0.5%(V/F), ±0.02%(PG close loop vector control) |
||
Speed fluctuation |
±0.3%(PG close loop vector control) |
||
Torque response |
|
||
Torque control accuracy |
5%(PG close loop vector control) |
||
Starting torque |
0Hz/200%(PG close loop vector control) |
||
Basic function |
Starting frequency |
0.00~10.00Hz |
|
ACC and DEC time |
0.1~3000.0s |
||
Carrier frequency |
1.0KHz~16.0KHz |
||
Frequency setting |
UP/DOWN setup, digital setup, analog quantity setting, pulse frequency setting, multi-step speed setting, PID setting, MODBUS communication setting, PROFIBUS communication setting, etc. |
||
Starting mode |
Start with starting frequency, start after DC brake |
||
Stop mode |
Deceleration stop, free stop, deceleration stop with DC brake or magnetic flux brake |
||
Motor type |
Asynchronous motor, permanent magnet synchronous motor |
||
Energy braking capacity |
Operating voltage of braking unit: 320~750V |
||
DC braking capability |
DC braking frequency: 0~300Hz; DC braking waiting time: 0~50s; DC braking current: 0.0~100.0%; DC braking time: 0.0~50.0s; |
||
Auto voltage adjustment |
Keep a stable output voltage automatically when the grid voltage transients |
||
Instantaneous frequency down |
Reduce frequency instantly to keep bus voltage stable when grid voltage is under-voltage. |
||
Control terminals |
Digital input |
Standard 10-channel inputs |
|
Analog input |
Standard 3-channel inputs, AI1: 0~10V or 0~20mA input optional, AI2: 0~10V or 0~20mA input optional,AI3: -10V~+10V input. |
||
Digital output |
Standard 2-channel multi-function collector outputs, one of which can be high-speed pulse output (HDO). |
||
Analog output |
Standard 2-channel outputs AO1, AO2 (0~10V or 4~20mA optional) |
||
Relay output |
Standard 2-channel relay outputs |
||
Communication interface |
RS485 communication |
RS485 communication interface for external RS485 communication, Modbus protocol (RTU mode) |
|
Extended communication port |
Various communication ports for expansion |
Support for Profibus, CANopen, Ethernet communication. |
|
Fault protection |
ACC over-current, DEC over-current, constant speed over-current, ACC over-voltage, DEC over-voltage, constant speed over-voltage, busbar under voltage, motor overload, inverter overload, input power failure, output phase loss, rectifier module overheating, inverter module overheating, external fault, communication fault, current detection fault, etc. |
||
Keypad display |
LED display |
Highlight LED digital tube displays the inverter information. |
|
LCD display |
LCD displays inverter information. |
||
Others |
Running environment |
Indoors, less than 1km above sea level, without dust, corrosive gases or direct sunlight |
|
Ambient temperature |
-10~+40℃, derate 1% for every additional 1℃ when the ambient temperature is between 40~50℃ |
||
Humidity |
5~95% (no condensation) |
||
Altitude |
0~2000m, derate 1% for every additional 100m when the sea level is above 1000m |
||
Vibration |
Less than 0.5g |
||
Storage temperature |
−40~+70℃ |