Mr.Thoi |
- 0909 462 075 | |
ATIC | - (028) 2253 4314 |
Hotline:
0909 462 075 (Mr. Thoi)
CT113 special inverter for middle and high frequency power supply
Benefits:
Inverter type |
Input current(A) |
Output current(A) |
Power capacity(KW) |
CT113-4T-0.7 |
5.0 |
3.8 |
1.5 |
CT113-4T-1.5 |
5.8 |
5.3 |
2.1 |
CT113-4T-2.2 |
12.0 |
9.5 |
3.7 |
CT113-4T-4.0 |
18.5 |
14.0 |
5.4 |
CT113-4T-5.5 |
22.5 |
18.5 |
7.1 |
CT113-4T-7.5 |
30.0 |
25.0 |
9.5 |
CT113-4T-11 |
39.0 |
32.0 |
12.2 |
CT113-4T-15 |
45.0 |
38.0 |
14.5 |
CT113-4T-18.5 |
54.0 |
45.0 |
17.1 |
CT113-4T-22 |
68.0 |
60.0 |
22.8 |
CT113-4T-30 |
84.0 |
75.0 |
28.5 |
CT113-4T-37 |
98.0 |
92.0 |
35.0 |
CT113-4T-45 |
123.0 |
115.0 |
43.7 |
CT113-4T-55 |
157.0 |
150.0 |
57.0 |
CT113-4T-75 |
188.0 |
180.0 |
68.4 |
CT113-4T-90 |
221.0 |
215.0 |
81.7 |
CT113-4T-110 |
267.0 |
260.0 |
98.8 |
CT113-4T-132 |
309.0 |
305.0 |
115.9 |
CT113-4T-160 |
344.0 |
340.0 |
129.2 |
CT113-4T-185 |
384.0 |
380.0 |
144.4 |
CT113-4T-200 |
429.0 |
425.0 |
161.5 |
CT113-4T-220 |
484.0 |
480.0 |
182.4 |
CT113-4T-250 |
539.0 |
530.0 |
201.4 |
CT113-4T-280 |
612.0 |
600.0 |
228.0 |
CT113-4T-315 |
665.0 |
650.0 |
247.0 |
CT113-4T-400 |
785.0 |
790.0 |
273.6 |
CT113-4T-500 |
890.0 |
950.0 |
326.8 |
CT113-4T-630 |
1230.0 |
1200.0 |
456.0 |
CT113-4T-700 |
1330.0 |
1300.0 |
494.0 |
CT113-4T-800 |
1500.0 |
1440.0 |
547.2 |
CT113-4T-1000 |
1780.0 |
1720.0 |
653.6 |
Input and output parameters |
Input voltage |
3PH 380VAC±15%. |
|
Input frequency |
50~60Hz±5% |
||
Output voltage |
0~Rated input voltage |
||
Output frequency |
50~3000Hz |
||
Technical control parameters |
Control mode |
current control, voltage control |
|
Overload capacity |
150% of rated current: 60s; 180% of rated current: 10s; 200% of rated current: 1s |
||
ACC and DEC time |
0.1~3000.0s |
||
Frequency setting |
Keypad setting, analog quantity setting, multi-step speed setting, PID setting, 485 communication setting |
||
Output voltage setting method |
Keypad setting, analog quantity setting, multi-step speed setting, PID setting, 485 communication setting |
||
Control terminals |
Digital input |
Standard 5-channel inputs |
|
Analog input |
Standard 2-channel inputs,AI0:0~10V keyboard knob, AIN: -10~10V input optional. |
||
Communication interface |
RS485 communication |
RS485 communication interface for external RS485 communication, Modbus protocol (RTU mode) |
|
Fault protection |
ACC over-current, DEC over-current, constant speed over-current, ACC over-voltage, DEC over-voltage, constant speed over-voltage, busbar under voltage, motor overload, inverter overload, input power failure, output phase loss, rectifier module overheating, inverter module overheating, external fault, communication fault, current detection fault, etc. |
||
Keypad display |
LED display |
Highlight LED digital tube displays the inverter information |
|
Others |
Running environment |
Indoors, less than 1km above sea level, without dust, corrosive gases or direct sunlight |
|
Ambient temperature |
-10~+40℃, derate 1% for every additional 1℃ when the ambient temperature is between 40~50℃ |
||
Humidity |
5~95% (no condensation) |
||
Altitude |
0~2000m, derate 1% for every additional 100m when the sea level is above 1000m |
||
Vibration |
Less than 0.5g |
||
Storage temperature |
−40~+70℃ |