Mr.Thoi |
- 0909 462 075 | |
ATIC | - (028) 2253 4314 |
Hotline:
0909 462 075 (Mr. Thoi)
Water supply delicated logic description:
CT111 is equipped with vectorized V/F control and constant pressure water supply dedicated logic, it can reach one inverter drives 3 pumps, and determine automatically amount of working pumps, thus getting water pressure constant all the time.
CT111 serise inverter is based on CT100 series, the power level is same with CT110.
Inverter model |
Power (kW) |
Input current (A) |
Output current (A) |
Applicable motor power (kW) |
Single-phase 220Vac 50/60Hz |
||||
CT110-2S-0.7G-B |
0.75 |
8.2 |
4.5 |
0.75 |
CT110-2S-1.5G-B |
1.5 |
14.0 |
7.0 |
1.5 |
CT110-2S-2.2G-B |
2.2 |
23.0 |
10 |
2.2 |
Three-phase 380Vac 50/60Hz |
||||
CT110-4T-0.7G-B |
0.75 |
3.4 |
2.5 |
0.75G |
CT110-4T-1.5G-B |
1.5 |
5.0 |
3.8 |
1.5G |
CT110-4T-2.2G-B |
2.2 |
5.8 |
5.3 |
2.2G |
CT110-4T-4.0G/5.5P-B |
4.0 |
12.0 |
9.5 |
4.0G |
5.5 |
18.5 |
14 |
5.5P |
|
CT110-4T-5.5G/7.5P-B |
5.5 |
18.5 |
14 |
5.5G |
7.5 |
22.5 |
18.5 |
7.5P |
|
CT110-4T-7.5G/11P-B |
7.5 |
22.5 |
18.5 |
7.5G |
11 |
30.0 |
25.0 |
11P |
|
CT110-4T-11G/15P-B |
11 |
30.0 |
25.0 |
11G |
15 |
39.0 |
32.0 |
15P |
|
CT110-4T-15G/18.5P-B |
15 |
39.0 |
32.0 |
15G |
18.5 |
45.0 |
38.0 |
18.5P |
|
CT110-4T-18.5G/22P-B |
18.5 |
45.0 |
38.0 |
18.5G |
22 |
54.0 |
45.0 |
22P |
|
CT110-4T-22G/30P-B |
22 |
54.0 |
45.0 |
22G |
30 |
68.0 |
60.0 |
30P |
|
CT110-4T-30G/37P-B |
30 |
68.0 |
60.0 |
30G |
37 |
84.0 |
75.0 |
37P |
|
CT110-4T-37G/45P-B |
37 |
84.0 |
75.0 |
37G |
45 |
98.0 |
92.0 |
45P |
|
CT110-4T-45G/55P |
45 |
98.0 |
92.0 |
45G |
55 |
123.0 |
115.0 |
55P |
|
CT110-4T-55G/75P |
55 |
123.0 |
115.0 |
55G |
75 |
157.0 |
150.0 |
75P |
|
CT110-4T-75G/90P |
75 |
157.0 |
150.0 |
75G |
90 |
188.0 |
180.0 |
90P |
|
CT110-4T-90G/110P |
90 |
188.0 |
180.0 |
90G |
110 |
221.0 |
215.0 |
110P |
|
CT110-4T-110G/132P |
110 |
221.0 |
215.0 |
110G |
132 |
267.0 |
260.0 |
132P |
|
CT110-4T-132G/160P |
132 |
267.0 |
260.0 |
132G |
160 |
309.0 |
305.0 |
160P |
|
CT110-4T-160G/185P |
160 |
309.0 |
305.0 |
160G |
185 |
344.0 |
340.0 |
185P |
|
CT110-4T-185G/200P |
185 |
344.0 |
340.0 |
185G |
200 |
384.0 |
380.0 |
200P |
|
CT110-4T-200G/220P |
200 |
384.0 |
380.0 |
200G |
220 |
429.0 |
425.0 |
220P |
|
CT110-4T-220G/250P |
220 |
429.0 |
425.0 |
220G |
250 |
484.0 |
480.0 |
250P |
|
CT110-4T-250G/280P |
250 |
484.0 |
480.0 |
250G |
280 |
539.0 |
530.0 |
280P |
|
CT110-4T-280G/315P |
280 |
539.0 |
530.0 |
280G |
315 |
612.0 |
600.0 |
315P |
|
CT110-4T-315G/355P |
315 |
612.0 |
600.0 |
315G |
355 |
Input and output parameters |
Input voltage |
1PH 220VAC±15%, 3PH 380VAC±15%. |
|
Input frequency |
50~60Hz±5% |
||
Output voltage |
0~Rated input voltage |
||
Output frequency |
0~600Hz |
||
Technical control parameters |
Control mode |
V/F control |
|
Adjustable-speed ratio |
Vector V/F control 1: 100 |
||
Speed control accuracy |
±0.5% |
||
Starting frequency |
0.00~10.00Hz |
||
Overload capacity |
150% of rated current: 60s; 180% of rated current: 10s; 200% of rated current: 1s |
||
ACC and DEC time |
0.1~3000.0s |
||
Energy braking capacity |
Operating voltage of braking unit: 320~750V |
||
DC braking capability |
DC braking frequency: 0~300Hz; DC braking waiting time: 0~50s; DC braking current: 0.0~100.0%; DC braking time: 0.0~50.0s; |
||
Frequency setting |
Keypad setting, analog quantity setting, multi-step speed setting, PID setting, 485 communication setting |
||
Auto voltage adjustment |
Keep a stable output voltage automatically when the grid voltage transients |
||
Speed tracking |
Start the rotating motor smoothly |
||
Control terminals |
Digital input |
Standard 5-channel inputs |
|
Analog input |
Standard 2-channel inputs,AI0:0~10V keyboard knob, AIN: 0~10V or 0~20mA input optional. |
||
Relay output |
Standard 2-channel relay outputs |
||
Communication interface |
RS485 communication |
RS485 communication interface for external RS485 communication, Modbus protocol (RTU mode) |
|
Fault protection |
ACC over-current, DEC over-current, constant speed over-current, ACC over-voltage, DEC over-voltage, constant speed over-voltage, busbar under voltage, motor overload, inverter overload, input power failure, output phase loss, rectifier module overheating, inverter module overheating, external fault, communication fault, current detection fault, etc. |
||
Keypad display |
LED display |
Highlight LED digital tube displays the inverter information |
|
LCD display |
LCD displays inverter information. |
||
Others |
Running environment |
Indoors, less than 1km above sea level, without dust, corrosive gases or direct sunlight |
|
Ambient temperature |
-10~+40℃, derate 1% for every additional 1℃when the ambient temperature is between 40~50℃ |
||
Humidity |
5~95% (no condensation) |
||
Altitude |
0~2000m, derate 1% for every additional 100m when the sea level is above 1000m |
||
Vibration |
Less than 0.5g |
||
Storage temperature |
−40~+70℃ |
||
Protection class |
IP20 |